dosimetry:userguide:userguide
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
dosimetry:userguide:userguide [2015/08/11 19:08] – [Improper System Usage] kerhart | dosimetry:userguide:userguide [2021/07/29 18:23] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 79: | Line 79: | ||
* [[dosimetry: | * [[dosimetry: | ||
* [[dosimetry: | * [[dosimetry: | ||
- | ==== Dose Calculation Functions ==== | ||
- | Detailed function and data type definitions can be found at [[http:// | ||
- | * **[[dosimetry: | + | * **[[dosimetry: |
- | * [[dosimetry: | + | * [[dosimetry: |
- | | + | ==== Dose Calculation Functions ==== |
+ | |||
+ | Detailed function and data type definitions can be found at [[http:// | ||
+ | * [[dosimetry: | ||
+ | * [[dosimetry: | ||
+ | * [[dosimetry: | ||
==== Radiotherapy Support Functions ==== | ==== Radiotherapy Support Functions ==== | ||
Line 95: | Line 98: | ||
* [[dosimetry: | * [[dosimetry: | ||
* [[dosimetry: | * [[dosimetry: | ||
+ | * [[dosimetry: | ||
Line 156: | Line 160: | ||
- **Large array_types of number_types** create issues with uploading to the ISS provider if the points are too dense. | - **Large array_types of number_types** create issues with uploading to the ISS provider if the points are too dense. | ||
- Consider keeping arrays of numbers from being overly large. | - Consider keeping arrays of numbers from being overly large. | ||
+ | - **PBS Dose Calculation Functions** accept the input type of proton_degrader, | ||
+ | - Currently only constant thickness range-shifters are validated for clinical use. | ||
Should you discover or suspect any additional errors or limitations not noted above, please contact the .decimal astroid Dosimetry App development lead, Kevin, Erhart, at kerhart@dotdecimal.com with details of your concerns. All concerns will be addressed as quickly as possible and follow up with the submitter will occur throughout the inquire and correction process. | Should you discover or suspect any additional errors or limitations not noted above, please contact the .decimal astroid Dosimetry App development lead, Kevin, Erhart, at kerhart@dotdecimal.com with details of your concerns. All concerns will be addressed as quickly as possible and follow up with the submitter will occur throughout the inquire and correction process. |