dosimetry:userguide:userguide

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
dosimetry:userguide:userguide [2018/04/10 15:58] – [Known Application Limitations] dpatenaudedosimetry:userguide:userguide [2021/07/29 18:23] (current) – external edit 127.0.0.1
Line 79: Line 79:
     * [[dosimetry:userguide:design_task_functions:dtf#compute_an_optimized_range_compensator|Compute an Optimized Range Compensator]]      * [[dosimetry:userguide:design_task_functions:dtf#compute_an_optimized_range_compensator|Compute an Optimized Range Compensator]] 
     * [[dosimetry:userguide:design_task_functions:dtf#patch_field_range_compensator|Patch Field Range Compensator]]      * [[dosimetry:userguide:design_task_functions:dtf#patch_field_range_compensator|Patch Field Range Compensator]] 
-==== Dose Calculation Functions ==== 
  
-Detailed function and data type definitions can be found at [[http://docs.apps.dotdecimal.com/dosimetry|Dosimetry Manifest Guide]]. Below are basic descriptions and details about the Dose Calculation Functions, dose modeling, and dose construction. 
  
-  * **[[dosimetry:userguide:dose_calculation_functions:dcf#sobp_dose_functionsSOBP Dose Functions]]**  +  * **[[dosimetry:userguide:design_task_functions:dtf#pbs_fluence_optimization|PBS Fluence Optimization ]]**: Explanation and sample process for PBS plan optimization functions 
-    * [[dosimetry:userguide:dose_calculation_functions:dcf#dose_calculation_modeling|Dose Calculation Modeling]] +    * [[dosimetry:userguide:design_task_functions:dtf#optimize_pbs_plan|Compute an Optimized PBS Plan]] 
-    [[dosimetry:userguide:dose_calculation_functions:dcf#construction_and_modeling|Construction and Modeling]]+==== Dose Calculation Functions ==== 
 + 
 +Detailed function and data type definitions can be found at [[http://docs.apps.dotdecimal.com/dosimetry|Dosimetry Manifest Guide]]. Below are basic descriptions of the available dose functions and details about the dose calculation algorithm and dose modeling.
  
 +  * [[dosimetry:userguide:dose_calculation_functions:dcf#pbs_dose_functions| PBS Dose Functions]] 
 +  * [[dosimetry:userguide:dose_calculation_functions:dcf#sobp_dose_functions| SOBP Dose Functions]]
 +  * [[dosimetry:userguide:dose_calculation_functions:dcf#dose_calculation_modeling|Dose Calculation & Modeling]]
 ==== Radiotherapy Support Functions ==== ==== Radiotherapy Support Functions ====
  
Line 95: Line 98:
     * [[dosimetry:userguide:radiotherapy_support_functions:rsf#contour_and_structure_modification|Contour and Structure Modification]]     * [[dosimetry:userguide:radiotherapy_support_functions:rsf#contour_and_structure_modification|Contour and Structure Modification]]
     * [[dosimetry:userguide:radiotherapy_support_functions:rsf#degrader_manipulation|Degrader Manipulation]]     * [[dosimetry:userguide:radiotherapy_support_functions:rsf#degrader_manipulation|Degrader Manipulation]]
 +    * [[dosimetry:userguide:radiotherapy_support_functions:rsf#pbs_layers|PBS Energy Layer Determinations]]
  
  
Line 157: Line 161:
     - Consider keeping arrays of numbers from being overly large.     - Consider keeping arrays of numbers from being overly large.
   - **PBS Dose Calculation Functions** accept the input type of proton_degrader, which allows for the use of a variable thickness range-compensator.   - **PBS Dose Calculation Functions** accept the input type of proton_degrader, which allows for the use of a variable thickness range-compensator.
-    - Currently only constant thickness range-shifters are supported.+    - Currently only constant thickness range-shifters are validated for clinical use.
  
 Should you discover or suspect any additional errors or limitations not noted above, please contact the .decimal astroid Dosimetry App development lead, Kevin, Erhart, at kerhart@dotdecimal.com with details of your concerns. All concerns will be addressed as quickly as possible and follow up with the submitter will occur throughout the inquire and correction process. Should you discover or suspect any additional errors or limitations not noted above, please contact the .decimal astroid Dosimetry App development lead, Kevin, Erhart, at kerhart@dotdecimal.com with details of your concerns. All concerns will be addressed as quickly as possible and follow up with the submitter will occur throughout the inquire and correction process.
dosimetry/userguide/userguide.1523375901.txt.gz · Last modified: 2021/07/29 18:21 (external edit)