planning:instructions_for_use:instructions_for_use
Differences
This shows you the differences between two versions of the page.
planning:instructions_for_use:instructions_for_use [2018/04/16 16:28] – [Overview and Indications for Use] kerhart | planning:instructions_for_use:instructions_for_use [2021/07/29 18:23] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 3: | Line 3: | ||
===== Overview and Indications for Use ===== | ===== Overview and Indications for Use ===== | ||
- | <WRAP caution>The Astroid Planning App is an interactive end user application for proton treatment planning for the intended use and primary purpose of enabling radiotherapy professionals to efficiently design and analyze proton radiotherapy treatment plans. This Astroid Planning App leverages the existing .decimal Astroid Dosimetry App [FDA 510(k) K150547], which is a library of treatment planning functions accessed through the Thinknode® cloud services framework, for device creation, dose calculation, | + | The Astroid Planning App is an interactive end user application for proton treatment planning for the intended use and primary purpose of enabling radiotherapy professionals to efficiently design and analyze proton radiotherapy treatment plans. This Astroid Planning App leverages the existing .decimal Astroid Dosimetry App [FDA 510(k) K150547], which is a library of treatment planning functions accessed through the Thinknode® cloud services framework, for device creation, dose calculation, |
Furthermore, | Furthermore, | ||
Line 206: | Line 206: | ||
* Constraints | * Constraints | ||
* Objectives | * Objectives | ||
+ | * Optional Fluence Override | ||
* Dose Results | * Dose Results | ||
Line 229: | Line 230: | ||
* A specific model of a target, OAR, or other structure. A physician may provide an initial target contour and a treatment plan generated using this information. The physician may later (using the same CT image set) provide a revised target contour. Rather than import this revision as a new structure or override the original, you may specify this new contour as a variant of the original. Each contour may have only a single " | * A specific model of a target, OAR, or other structure. A physician may provide an initial target contour and a treatment plan generated using this information. The physician may later (using the same CT image set) provide a revised target contour. Rather than import this revision as a new structure or override the original, you may specify this new contour as a variant of the original. Each contour may have only a single " | ||
* **__Plan__**: | * **__Plan__**: | ||
- | * A detailed model of a proton therapy treatment. Most aspects of the patient planning information are stored here (e.g. Beams, Fraction Groups, Optimization Information, | + | * A detailed model of a proton therapy treatment. Most aspects of the patient planning information are stored here (e.g. Beams, Fraction Groups, Optimization Information, |
==== Structures in the Data Model ==== | ==== Structures in the Data Model ==== |
planning/instructions_for_use/instructions_for_use.1523896097.txt.gz · Last modified: 2021/07/29 18:22 (external edit)