decimal3D Version History
This section is intended to provide access to previous versions of the decimal3D userguide documentation. Below you will find the userguide for each released version of the decimal3D App. To find your application's current version open the “Advanced” page from the left side menu.
User Guide information is directly available on this website and a PDF is provided for offline user guide access with each version below.
Release Notes
decimal3D 1.10.1 (Build 101)
decimal3D 1.10.0 (Build 96)
October 12, 2021 - Download the decimal3D 1.10.0 User Guide
What's New
Added support for Auth0 Log In:
Users added through decimal Direct with decimal3D permissions are capable of logging in via Auth0.
decimal3D will automatically check if a user is an Auth0 or legacy account and log you in accordingly.
decimal3D now pulls ordering addresses from decimal Direct. If the address is not present in decimal Direct then decimal3D will fall back to using the p.d machine address.
Removed the ability to log in offline.
Added a registered trademark insignia to decimal3D logos.
Added the ability to put hyphens in the patient's MRN.
Bug Fixes
Fixed a bug where editing a patient avatar would not replace the old one, resulting in the old one usually remaining displayed.
Fixed issue where the log in buttons and text boxes would be covered by the keyboard.
decimal3D 1.9.1 (Build 91)
July 28, 2021 - Download the decimal3D 1.9.1 User Guide
What's New
Updated DICOM RT Plan output to include Applicator Sequence and generic Prescription/Dose Reference fields to improve R&V compatibility
Added Advanced Setting to allow users to turn on automatic filling of billing PO numbers
Various minor bug fixes and usability improvements are also included
Bug Fixes
decimal3D 1.9.0 (Build 87)
June 21, 2021 - Download the decimal3D 1.9.0 User Guide
What's New
Bug Fixes
Completing a scan no longer directs you straight into contour creation
Fixed error causing front-facing camera photos to appear inverted
Added better error message for expired passwords
Fixed an issue that allowed rotation of BEV
Disabled contour and beam creation until a treatment machine has been selected
decimal3D 1.8.0 (Build 58)
decimal3D 1.7.0 (Build 53)
decimal3D 1.6.1 (Build 42)
November 16, 2020 - Download the decimal3D 1.6.0 User Guide (no User Changes are associated this release)
What's New
This release includes updates to support iOS v14 and the Occipital SDK v1.0.
Additionally, the DICOM export now provides improved status messages.
decimal3D 1.6.0 (Build 39)
decimal3D 1.5.0 (Build 36)
decimal3D 1.4.0 (Build 35)
July 09, 2020 - Download decimal3D 1.4.0 User Guide
What's New
Bug Fixes
Patient Name fields split out into First, Middle, and Last
Restyled the Advanced page and added DICOM Receiver configuration data
decimal3D 1.3.0 (Build 28)
May 28, 2020 - Download decimal3D 1.3.0 User Guide
This is a minor release focused on usability enhancements. The most notable addition is this release is the incorporation of machine parameters to allow displays to use the local user's equipment angle settings within the application (top item below). Additional items of note are included below:
What's New
Machine definitions now read rotation direction and reference positions for gantry, couch, and collimator rotations (i.e. IEC or vendor-specific equipment configurations are now supported)
Several confirmations were added in cases where the attempted action may result in loss of unsaved data (e.g. cancelling a beam edit or discarding a scan)
iPad App orientation is locked to landscape right to prevent unexpected scanning behavior on screen rotation
Bug Fixes
decimal3D 1.2.0 (Build 25)
March 23, 2020 - Download decimal3D 1.2.0 User Guide
What's New
Added couch angle calculation when defining the initial beam entry position
Added millability enforcement to cutout shapes and warnings to users when 1.5mm or greater deviations are found
Reduced contour drawing “dwell times” to improve usability and fixed some bugs with undo/redo
Added the SiteID to the Order Page
Added an additional “edit scan” button to the Scan Details view
Removed emoji keyboard options when adding/editing patient information
Bug Fixes
Increased spinner sizes and spacings, and added “wrap around” support to improve usability of beam editing
Updated DOB spinner default and allow forward dates (but warn on save attempt as this greatly improves usability)
Fixed keyboard positioning to prevent covering of input controls on certain pages
Fixed a bug where hitting cancel on the beam Save confirmation would close the beam task, thereby deleting user changes
Fixed errors with allowable block size determination and potential saving of the wrong block size and app crashing
Changed crosshair color and line thickness
decimal3D 1.1.0 (Build 20)
January 28, 2020 Download decimal3D 1.1.0 User Guide
This version was the first release intended for clinical use.
.decimal LLC, 121 Central Park Place, Sanford, FL 32771. 1-800-255-1613