User Tools

Site Tools


decimal3d:instructions_for_use:instructions_for_use

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
decimal3d:instructions_for_use:instructions_for_use [2019/11/29 13:05] – [System Availability and Data Integrity] kerhartdecimal3d:instructions_for_use:instructions_for_use [2019/11/29 13:10] – [System Calibration] kerhart
Line 45: Line 45:
 The following is a list of several important items that users should understand in regards to the information displays in the decimal3D Application: The following is a list of several important items that users should understand in regards to the information displays in the decimal3D Application:
  
-  * All linear dimensions are shown in millimeters (mm)+  * All linear dimensions are shown in centimeters (cm)
   * All angular dimensions are shown in degrees (deg)   * All angular dimensions are shown in degrees (deg)
   * All date/time values are provided in a // mm/dd/yyyy h:m:s am/pm // format using local time   * All date/time values are provided in a // mm/dd/yyyy h:m:s am/pm // format using local time
Line 61: Line 61:
 ==== System Calibration ==== ==== System Calibration ====
  
-The decimal3D application relies on both the Structure Sensor and built-in iPad color camera. Proper operation of the decimal3D App requires that these two components be properly calibrated to ensure accurate alignment of scanned image colorization. A calibrator app has been provided with your iPad and the system is shipped pre-calibrated. However, part of the regular maintenance of the decimal3D application is for users to verify and adjust the calibration every 6 months OR anytime the Structure Sensor is removed from the iPad OR anytime the system is subjected to an impact (e.g. fall or drop) that may have jarred or shifted the Structure Sensor. The calibration procedure is simple and the provided calibrator app walks users through adjusting and testing the system's calibration.+The decimal3D application relies on both the Structure Sensor Mark II and built-in iPad color camera. Proper operation of the decimal3D App requires that these two components be properly calibrated to ensure accurate alignment of scanned image colorization. A calibrator app has been provided with your iPad and the system is shipped pre-calibrated. However, part of the regular maintenance of the decimal3D application is for users to verify and adjust the calibration every 6 months OR anytime the Structure Sensor is removed from the iPad OR anytime the system is subjected to an impact (e.g. fall or drop) that may have jarred or shifted the Structure Sensor. The calibration procedure is simple and the provided calibrator app walks users through adjusting and testing the system's calibration.
 ===== Known Limitations ===== ===== Known Limitations =====
  
decimal3d/instructions_for_use/instructions_for_use.txt · Last modified: 2023/04/17 16:34 by kerhart