Line 45: Line 45:
 The following is a list of several important items that users should understand in regards to the information displays in the decimal3D Application: The following is a list of several important items that users should understand in regards to the information displays in the decimal3D Application:
  
-  * All linear dimensions are shown in millimeters (mm)+  * All linear dimensions are shown in centimeters (cm)
   * All angular dimensions are shown in degrees (deg)   * All angular dimensions are shown in degrees (deg)
   * All date/time values are provided in a // mm/dd/yyyy h:m:s am/pm // format using local time   * All date/time values are provided in a // mm/dd/yyyy h:m:s am/pm // format using local time
Line 61: Line 61:
 ==== System Calibration ==== ==== System Calibration ====
  
-The decimal3D application relies on both the Structure Sensor and built-in iPad color camera. Proper operation of the decimal3D App requires that these two components be properly calibrated to ensure accurate alignment of scanned image colorization. A calibrator app has been provided with your iPad and the system is shipped pre-calibrated. However, part of the regular maintenance of the decimal3D application is for users to verify and adjust the calibration every 6 months OR anytime the Structure Sensor is removed from the iPad OR anytime the system is subjected to an impact (e.g. fall or drop) that may have jarred or shifted the Structure Sensor. The calibration procedure is simple and the provided calibrator app walks users through adjusting and testing the system's calibration.+The decimal3D application relies on both the Structure Sensor Mark II and built-in iPad color camera. Proper operation of the decimal3D App requires that these two components be properly calibrated to ensure accurate alignment of scanned image colorization. A calibrator app has been provided with your iPad and the system is shipped pre-calibrated. However, part of the regular maintenance of the decimal3D application is for users to verify and adjust the calibration every 6 months OR anytime the Mark II Sensor is removed from the iPad OR anytime the system is subjected to an impact (e.g. fall or drop) that may have jarred or shifted the Sensor. The calibration procedure is simple and the provided calibrator app walks users through adjusting and testing the system's calibration. 
 ===== Known Limitations ===== ===== Known Limitations =====
  
Line 70: Line 71:
   - User passwords cannot be changed within the decimal3D App (please log in to direct.dotdecimal.com to change your password or contact .decimal customer service to request a password reset)   - User passwords cannot be changed within the decimal3D App (please log in to direct.dotdecimal.com to change your password or contact .decimal customer service to request a password reset)
   - Patient Databases are stored locally on each iPad, so facilities with more than one iPad will not be able to access all patient records from each iPad (note: once an Order is place however, the order information is available via direct.dotdecimal.com, which can be accessed from any device or computer)   - Patient Databases are stored locally on each iPad, so facilities with more than one iPad will not be able to access all patient records from each iPad (note: once an Order is place however, the order information is available via direct.dotdecimal.com, which can be accessed from any device or computer)
-  - Once a scan has been created its name cannot be edited (scan names are for convenience only and are used elsewhere in the application) +  - Once a scan has been created its name cannot be edited (scan names are for convenience only and are used only for convenience in the application) 
-  - Once a beam has been created its name cannot be edited (beam names are used within the cutout engraving, therefore if an appropriate name was used, we recommend that you create a new beam with the desired name, using the same parameters, and then delete the wrongly named beam)+  - Once a beam has been created its name cannot be edited (beam names are used as part of the cutout engraving text, therefore if an appropriate name was used, we recommend that you create a new beam with the desired name, using the same parameters, and then delete the wrongly named beam) 
 ===== Release Notes ===== ===== Release Notes =====
  
-For the release notes for each version of the Planning Application, please refer to [[decimal3d:app_versions|decimal3D Version History]].+For the release notes for each version of the decimal3D Application, please refer to [[decimal3d:app_versions|decimal3D Version History]].
  
  