User Tools

Site Tools


decimal3d:instructions_for_use:instructions_for_use

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
decimal3d:instructions_for_use:instructions_for_use [2019/11/29 13:05] – [System Availability and Data Integrity] kerhartdecimal3d:instructions_for_use:instructions_for_use [2020/06/25 16:50] – [Product Features] kerhart
Line 33: Line 33:
 ===== Product Features ===== ===== Product Features =====
  
-decimal3D is a medical software accessed on an iPad and managed through the Apple App Store®. decimal3D allows users to enter standard patient information, capture a three dimensional scan of the physician drawn treatment area, digitize the exact shape of the treatment field, and place a beam to complete the design of a patient-specific electron aperture. The decimal3D App also allows the user to order the aperture for fabrication and delivery by .decimal.+decimal3D is a medical software accessed on an iPad and managed through the Apple App Store® (users must create an account with Apple to manage their iPad software installations). decimal3D allows users to enter standard patient information, capture a three dimensional scan of the physician drawn treatment area, digitize the exact shape of the treatment field, and place a beam to complete the design of a patient-specific electron aperture. The decimal3D App also allows the user to order the aperture for fabrication and delivery by .decimal. Ordered Treatment Devices can also be exported to R&V and other software systems via the built in DICOM file sender.
  
 ==== System Availability and Data Integrity ==== ==== System Availability and Data Integrity ====
Line 45: Line 45:
 The following is a list of several important items that users should understand in regards to the information displays in the decimal3D Application: The following is a list of several important items that users should understand in regards to the information displays in the decimal3D Application:
  
-  * All linear dimensions are shown in millimeters (mm)+  * All linear dimensions are shown in centimeters (cm)
   * All angular dimensions are shown in degrees (deg)   * All angular dimensions are shown in degrees (deg)
   * All date/time values are provided in a // mm/dd/yyyy h:m:s am/pm // format using local time   * All date/time values are provided in a // mm/dd/yyyy h:m:s am/pm // format using local time
Line 61: Line 61:
 ==== System Calibration ==== ==== System Calibration ====
  
-The decimal3D application relies on both the Structure Sensor and built-in iPad color camera. Proper operation of the decimal3D App requires that these two components be properly calibrated to ensure accurate alignment of scanned image colorization. A calibrator app has been provided with your iPad and the system is shipped pre-calibrated. However, part of the regular maintenance of the decimal3D application is for users to verify and adjust the calibration every 6 months OR anytime the Structure Sensor is removed from the iPad OR anytime the system is subjected to an impact (e.g. fall or drop) that may have jarred or shifted the Structure Sensor. The calibration procedure is simple and the provided calibrator app walks users through adjusting and testing the system's calibration.+The decimal3D application relies on both the Structure Sensor Mark II and built-in iPad color camera. Proper operation of the decimal3D App requires that these two components be properly calibrated to ensure accurate alignment of scanned image colorization. A calibrator app has been provided with your iPad and the system is shipped pre-calibrated. However, part of the regular maintenance of the decimal3D application is for users to verify and adjust the calibration every 6 months OR anytime the Mark II Sensor is removed from the iPad OR anytime the system is subjected to an impact (e.g. fall or drop) that may have jarred or shifted the Sensor. The calibration procedure is simple and the provided calibrator app walks users through adjusting and testing the system's calibration. 
 ===== Known Limitations ===== ===== Known Limitations =====
  
 Below are listed the known application limitations, defects, or inconsistencies. Below are listed the known application limitations, defects, or inconsistencies.
  
-  - Treatment position information (e.g. isocenter, gantry angle, couch angle, collimator angle) is not available at this time as there is no sufficient link between the scanner coordinate and treatment machine coordinate systems 
   - Site information including Machine and Address Settings cannot be edited from decimal3D (these can be edited using .decimal's p.d software available on Windows computers)   - Site information including Machine and Address Settings cannot be edited from decimal3D (these can be edited using .decimal's p.d software available on Windows computers)
   - User passwords cannot be changed within the decimal3D App (please log in to direct.dotdecimal.com to change your password or contact .decimal customer service to request a password reset)   - User passwords cannot be changed within the decimal3D App (please log in to direct.dotdecimal.com to change your password or contact .decimal customer service to request a password reset)
   - Patient Databases are stored locally on each iPad, so facilities with more than one iPad will not be able to access all patient records from each iPad (note: once an Order is place however, the order information is available via direct.dotdecimal.com, which can be accessed from any device or computer)   - Patient Databases are stored locally on each iPad, so facilities with more than one iPad will not be able to access all patient records from each iPad (note: once an Order is place however, the order information is available via direct.dotdecimal.com, which can be accessed from any device or computer)
-  - Once a scan has been created its name cannot be edited (scan names are for convenience only and are used elsewhere in the application) +  - Scans are able to be deleted even if they contain contours and beams, so care should be exercised whenever deleting scans as all data associated with that scan will also be deleted 
-  - Once a beam has been created its name cannot be edited (beam names are used within the cutout engravingtherefore if an appropriate name was used, we recommend that you create a new beam with the desired nameusing the same parameters, and then delete the wrongly named beam)+  - Very bright indoor lighting can interfere with scanningespecially on dark or shiny surfaces; if you experience difficulty with the scanner recognizing a surfacetry scanning in a lower light condition 
 ===== Release Notes ===== ===== Release Notes =====
  
-For the release notes for each version of the Planning Application, please refer to [[decimal3d:app_versions|decimal3D Version History]].+For the release notes for each version of the decimal3D Application, please refer to [[decimal3d:app_versions|decimal3D Version History]].
  
  
 ---- ----
-<WRAP center 60%>.decimal LLC, 121 Central Park Place Sanford, FL32771 1-800-255-1613</WRAP>+<WRAP center 60%>.decimal LLC, 121 Central Park PlaceSanford, FL 327711-800-255-1613</WRAP>
  
    
decimal3d/instructions_for_use/instructions_for_use.txt · Last modified: 2023/04/17 16:34 by kerhart