decimal3d:instructions_for_use:customer_walkthrough
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
decimal3d:instructions_for_use:customer_walkthrough [2019/10/24 20:27] – kmobile | decimal3d:instructions_for_use:customer_walkthrough [2021/07/29 18:23] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | ===== Walk-through ===== | + | ====== Electron Block Walk-through |
- | This walk-through is intended to be an easy to follow step-by-step guide for a " | + | This walk-through is intended to be an easy to follow step-by-step guide for completing |
- | - Have the physician outline the treatment area in the exam room | + | - Have the physician outline the desired |
- | - Open the decimal3D app on the iPad and login with user name and password{{{{: | + | - Bring the patient to the simulator or treatment |
- | - Bring the patient to the simulator or treatment room | + | - Open the decimal3D app on the iPad and login with your unique username |
- | - Select //New Patient// in the top right hand of the Patient Management Screen | + | - Select //New Patient// in the top right hand of the Patient Management Screen {{ : |
- | - Enter //Patient Name// | + | - Enter the //Patient Name// |
- | - Enter //Date of Birth// | + | - Enter the //Date of Birth// {{ : |
- | - Select patient //Gender// from drop down {{ : | + | - Select |
- | - Enter //MRN// (Medical Record Number){{ : | + | - Enter the //MRN// (Medical Record Number){{ : |
- | - The user may select the enter the // | + | - If desired, |
- | - Select | + | - Press //Submit// and the patient |
- | - In the top right hand corner select //New Scan// {{ : | + | - In the top right hand corner select //New Scan// {{ : |
- | - Select | + | - Before starting the scan, you must align the iPad to the treatment table so that couch and gantry angles can be accurately determined |
- | | + | - To perform this alignment, simply hold the iPad against the edge of the treatment table (with the gantry toward YOUR LEFT and the iPad parallel to the floor) and press the //Align// button |
- | - As the scan is rendering it will appear white{{ : | + | |
- | - One the scan is done processing | + | - The box shown in the app can also be adjusted to control the size of the area to be scanned. Only areas fully within the box will be captured during the scan, so you can use a two-finger pinch to shrink or expand the box as needed for the field size at hand. |
- | - If it the scan is not acceptable select | + | - Once you are correctly positioned, press the //Scan// button to begin capturing data. {{ : |
- | - Choose the machine | + | - While the scan is active, the area that has been fully captured |
- | - Select //New Contours// {{ : | + | - Press the //Scan// button again to complete the scan. |
- | - //Draw Contour// | + | - The decimal3D app now automatically begins processing the scan depth and color data to produce the colorized 3D model |
- | - Once the user has completed | + | - Once the scan is done processing |
- | - If the user is satisfied with select | + | - If the scan is acceptable select |
- | - | + | - If it the scan is not acceptable select //New Scan// button on the left-hand side to discard this scan and start a new scan |
+ | - Choose the desired treatment | ||
+ | - Your scan is now saved and you are ready to digitize the treatment field | ||
+ | - Select //New Contour// | ||
+ | - You should now rotate, pan, and zoom the display to provide a good view of the treatment field | ||
+ | - Rotate by using a single finger drag in any direction | ||
+ | - Pan by using a two finger drag in any direction | ||
+ | - Zoom by using a two finger pinch motion anywhere in the display | ||
+ | - Now you will trace the physician drawn treatment field directly on the 3D patient model using either the Apple Pencil or your finger | ||
+ | - To start drawing dwell on the scanned image at the desired start point for a full second, then continue drawing the entire treatment area as a single closed contour. Continue drawing until the contour is closed back at the original start point (the contour will change colors to indicate it is now complete). If you lift the pencil/ | ||
+ | - Once you have closed the contour, the application will automatically switch to the //Adjust | ||
+ | - Once you're satisfied with the contour select the //Finish// button. Provide a name for the contour (or leave the name at the default) then press //Submit// to save the contour. | ||
+ | - You are now ready to create your electron aperture by specifying the treatment beam parameters (the application will automatically enter the beam creation task when the contour is completed). | ||
+ | - The first step in defining the beam is to select the contours to use for the aperture projection (note the contour is automatically selected when this task is started). Press the //Next// button to accept the contour selection. | ||
+ | - Now you will set the beam entry point by tapping on the patient model at the desired location. Tap again to change the location if needed, then press //Next// to accept this position | ||
+ | - You are now presented with all the remaining parameters needed to fully define | ||
+ | - These include: SSD, Applicator Size, Gantry Angle, Couch Angle, and Collimator Angle (note: as of v1.7 SSD now includes a second input that allows SSD setting | ||
+ | - Adjust | ||
+ | - You may also wish to rotate the model to ensure an appropriate treatment angle has been selected (and to check for possible collisions of the applicator with the patient). You can also switch to a Beam's Eye View (BEV) where you can view and measure the block shape (note the BEV shape is projected to the isocenter plane). | ||
+ | - Once you' | ||
+ | - You are now ready to order the cutout by pressing //Order// in the top right hand corner. | ||
+ | - All available cutouts are automatically selected for ordering and the engraving data for each cutout is shown at the top of the order page. | ||
+ | - Select a shipping priority, review the Shipping and Billing Address information, | ||
+ | - Wait for 30-60 seconds to receive a confirmation of successful order. | ||
+ | - Once your order has been placed, the DICOM Export option will become available. Simply click the " | ||
+ | - If you encounter any difficulties or problems contact our customer service team at 1.800.255.1613 | ||
decimal3d/instructions_for_use/customer_walkthrough.1571948852.txt.gz · Last modified: 2021/07/29 18:21 (external edit)