decimal3d:instructions_for_use:customer_walkthrough
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
decimal3d:instructions_for_use:customer_walkthrough [2020/01/03 21:08] – kerhart | decimal3d:instructions_for_use:customer_walkthrough [2021/07/29 18:23] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | ===== Walk-through ===== | + | ====== Electron Block Walk-through |
This walk-through is intended to be an easy to follow step-by-step guide for completing a " | This walk-through is intended to be an easy to follow step-by-step guide for completing a " | ||
Line 5: | Line 5: | ||
- Have the physician outline the desired treatment area on the patient' | - Have the physician outline the desired treatment area on the patient' | ||
- Bring the patient to the simulator or treatment room and place them in the desired treatment position | - Bring the patient to the simulator or treatment room and place them in the desired treatment position | ||
- | - Open the decimal3D app on the iPad and login with your unique username and password | + | - Open the decimal3D app on the iPad and login with your unique username and password. The username and password is the same as what is used to sign in to p.d. {{ : |
- Select //New Patient// in the top right hand of the Patient Management Screen {{ : | - Select //New Patient// in the top right hand of the Patient Management Screen {{ : | ||
- | - Enter the //Patient Name// | + | - Enter the //Patient Name// |
- | - Enter the //Date of Birth// {{ : | + | - Enter the //Date of Birth// {{ : |
- | - Select the patient //Gender// from drop down {{ : | + | - Select the patient //Gender// from drop down {{ : |
- | - Enter the //MRN// (Medical Record Number){{ : | + | - Enter the //MRN// (Medical Record Number){{ : |
- | - If desired, enter the // | + | - If desired, enter the // |
- | - Press //Submit// and the patient record will be created {{ : | + | - Press //Submit// and the patient record will be created {{ : |
- | - In the top right hand corner select //New Scan// {{ : | + | - In the top right hand corner select //New Scan// {{ : |
- | - Select the //New Scan// button on the left hand side {{ : | + | - Before starting the scan, you must align the iPad to the treatment table so that couch and gantry angles can be accurately determined |
- | - Before starting the scan, you must orient | + | - To perform this alignment, simply hold the iPad against the edge of the treatment table (with the gantry toward YOUR LEFT and the iPad parallel to the floor) and press the //Align// button as shown in the images below {{: |
- | - To perform this orientation, simply hold the iPad against the edge of the treatment table (with the gantry toward YOUR LEFT and the iPad parallel to the floor) and press the //Align// button as shown in the images below {{: | + | - You are now ready to scan the patient. Focus the scanner on the area to be scanned. Adjust your distance from the patient to ensure the entire area to be scanned appears in RED (red indicates an ideal scan distance, yellow is slightly too far away, and if no color is shown, you are too close to the patient). The ideal distance is about half a meter (18 to 24 inches). |
- | - You are now ready to scan the patient. Focus the scanner on the area to be scanned. Adjust your distance from the patient to ensure the entire area to be scanned appears in RED (red indicates an ideal scan distance, yellow is slightly too far away, and if no color is shown, you are too close to the patient). The ideal distance is about half a meter (18 to 24 inches) | + | |
- The box shown in the app can also be adjusted to control the size of the area to be scanned. Only areas fully within the box will be captured during the scan, so you can use a two-finger pinch to shrink or expand the box as needed for the field size at hand. | - The box shown in the app can also be adjusted to control the size of the area to be scanned. Only areas fully within the box will be captured during the scan, so you can use a two-finger pinch to shrink or expand the box as needed for the field size at hand. | ||
- Once you are correctly positioned, press the //Scan// button to begin capturing data. {{ : | - Once you are correctly positioned, press the //Scan// button to begin capturing data. {{ : | ||
- While the scan is active, the area that has been fully captured will appear white. You should continue scanning until the entire desired area is shown in white. For relatively smooth or flat areas, the scan can be obtained within 1-2 seconds without moving the iPad, but for larger or highly curved areas, you may need to slowly move or rotate the iPad to capture the entire patient surface. {{ : | - While the scan is active, the area that has been fully captured will appear white. You should continue scanning until the entire desired area is shown in white. For relatively smooth or flat areas, the scan can be obtained within 1-2 seconds without moving the iPad, but for larger or highly curved areas, you may need to slowly move or rotate the iPad to capture the entire patient surface. {{ : | ||
- Press the //Scan// button again to complete the scan. | - Press the //Scan// button again to complete the scan. | ||
- | - The decimal3D app now automatically | + | - The decimal3D app now automatically |
- Once the scan is done processing review the resulting model | - Once the scan is done processing review the resulting model | ||
- If the scan is acceptable select //Accept Scan// {{ : | - If the scan is acceptable select //Accept Scan// {{ : | ||
- If it the scan is not acceptable select //New Scan// button on the left-hand side to discard this scan and start a new scan | - If it the scan is not acceptable select //New Scan// button on the left-hand side to discard this scan and start a new scan | ||
- | - Choose the desired treatment machine from the scroll selector and edit the name of the scan if desired (by default scans are labeled with sequential numbers, e.g. //Scan 1//). Scan names are used only for convenience to locate scans within a patient and are not used for any other purpose in the application. Press //Submit// when done. {{ : | + | - Choose the desired treatment machine from the scroll selector and edit the name of the scan if desired (by default scans are labeled with sequential numbers, e.g. //Scan 1//). Scan names are used only as a convenience |
- | - Your scan is now complete and saved and you are ready to digitize the treatment field | + | - Your scan is now saved and you are ready to digitize the treatment field |
- | - Select //Contours// | + | - Select //New Contour// |
- | - Using either the Apple Pencil or a finger dwell on the scanned image for a second | + | - You should now rotate, pan, and zoom the display to provide a good view of the treatment field |
- | - Once the user has completed | + | - Rotate by using a single finger drag in any direction |
- | - If the user is satisfied with select the // | + | - Pan by using a two finger drag in any direction |
- | - To create the beam user must first select | + | - Zoom by using a two finger pinch motion anywhere in the display |
- | - The user can then rotate the patient and then will tap on the scan where they want to place the entry point and select | + | - Now you will trace the physician drawn treatment field directly on the 3D patient model using either the Apple Pencil or your finger |
- | - The user can then adjust any of the parameters | + | - To start drawing |
- | - The user may also rotate to ensure | + | - Once you have closed |
- | - If the user is satisfied | + | - Once you' |
- | - At this point the user may proceed | + | - You are now ready to create |
- | - The user must select | + | - The first step in defining |
+ | - Now you will set the beam entry point by tapping on the patient model at the desired location. Tap again to change the location if needed, then press // | ||
+ | - You are now presented with all the remaining | ||
+ | - These include: SSD, Applicator Size, Gantry Angle, Couch Angle, and Collimator Angle (note: as of v1.7 SSD now includes | ||
+ | - Adjust the parameters as needed to meet the clinical needs of the patient at hand. {{ : | ||
+ | - You may also wish to rotate | ||
+ | - Once you' | ||
+ | - You are now ready to order the cutout | ||
+ | - All available cutouts are automatically selected for ordering and the engraving data for each cutout is shown at the top of the order page. | ||
+ | - Select a shipping priority, review the Shipping and Billing Address information, | ||
+ | - Wait for 30-60 seconds to receive a confirmation of successful order. | ||
+ | - Once your order has been placed, the DICOM Export option will become available. Simply click the " | ||
+ | - If you encounter any difficulties or problems contact our customer service team at 1.800.255.1613 | ||
decimal3d/instructions_for_use/customer_walkthrough.1578085727.txt.gz · Last modified: 2021/07/29 18:21 (external edit)