decimal3d:instructions_for_use:customer_walkthrough
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
decimal3d:instructions_for_use:customer_walkthrough [2020/06/25 17:45] – kerhart | decimal3d:instructions_for_use:customer_walkthrough [2021/07/29 18:23] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | ===== Walk-through ===== | + | ====== Electron Block Walk-through |
This walk-through is intended to be an easy to follow step-by-step guide for completing a " | This walk-through is intended to be an easy to follow step-by-step guide for completing a " | ||
Line 40: | Line 40: | ||
- Now you will set the beam entry point by tapping on the patient model at the desired location. Tap again to change the location if needed, then press //Next// to accept this position {{ : | - Now you will set the beam entry point by tapping on the patient model at the desired location. Tap again to change the location if needed, then press //Next// to accept this position {{ : | ||
- You are now presented with all the remaining parameters needed to fully define the desired treatment beam. | - You are now presented with all the remaining parameters needed to fully define the desired treatment beam. | ||
- | - These include: SSD, Applicator Size, Gantry Angle, Couch Angle, and Collimator Angle | + | - These include: SSD, Applicator Size, Gantry Angle, Couch Angle, and Collimator Angle (note: as of v1.7 SSD now includes a second input that allows SSD setting to 0.1cm resolution) |
- Adjust the parameters as needed to meet the clinical needs of the patient at hand. {{ : | - Adjust the parameters as needed to meet the clinical needs of the patient at hand. {{ : | ||
- You may also wish to rotate the model to ensure an appropriate treatment angle has been selected (and to check for possible collisions of the applicator with the patient). You can also switch to a Beam's Eye View (BEV) where you can view and measure the block shape (note the BEV shape is projected to the isocenter plane). {{ : | - You may also wish to rotate the model to ensure an appropriate treatment angle has been selected (and to check for possible collisions of the applicator with the patient). You can also switch to a Beam's Eye View (BEV) where you can view and measure the block shape (note the BEV shape is projected to the isocenter plane). {{ : | ||
Line 48: | Line 48: | ||
- Select a shipping priority, review the Shipping and Billing Address information, | - Select a shipping priority, review the Shipping and Billing Address information, | ||
- Wait for 30-60 seconds to receive a confirmation of successful order. | - Wait for 30-60 seconds to receive a confirmation of successful order. | ||
- | - Once your order has been placed, the DICOM Export option will become available. Simply click the " | + | - Once your order has been placed, the DICOM Export option will become available. Simply click the " |
- If you encounter any difficulties or problems contact our customer service team at 1.800.255.1613 | - If you encounter any difficulties or problems contact our customer service team at 1.800.255.1613 | ||