electronrt:userguide:dicom_receiver
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
electronrt:userguide:dicom_receiver [2021/03/17 15:36] – [Running Modes] dpatenaude | electronrt:userguide:dicom_receiver [2021/07/29 18:23] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | ====== ElectronRT DICOM Receiver ====== | + | ====== ElectronRT DICOM Receiver |
The decimal ElectronRT application supports importing DICOM patients via a DICOM listener/ | The decimal ElectronRT application supports importing DICOM patients via a DICOM listener/ | ||
Line 5: | Line 5: | ||
===== DICOM Receiver ===== | ===== DICOM Receiver ===== | ||
- | The following guide details how to download, install, and configure the ElectronRT DICOM Receiver to automatically accept and import files into the ElectronRT application | + | The following guide details how to download, install, and configure the ElectronRT DICOM Receiver to automatically accept and import files into the ElectronRT application. |
==== Download and Installation ==== | ==== Download and Installation ==== | ||
- | - Download the ElectronRT DICOM Receiver via FIXME | + | - Download the ElectronRT DICOM Receiver via contacting .decimal for a secure download (note: future versions of eRT will include a DICOM receiver packaged with the application). |
- Extract the ElectronRT_dicom_receiver.zip file to an appropriate directory of your choosing (e.g.: C: | - Extract the ElectronRT_dicom_receiver.zip file to an appropriate directory of your choosing (e.g.: C: | ||
- Edit the receiver_config.json file to set the following fields: | - Edit the receiver_config.json file to set the following fields: | ||
- | - **local_ae_title**: | + | - **local_ae_title**: |
- | - **local_port**: | + | - **local_port**: |
- | - **timeout**: | + | - **timeout**: |
- | - **storage_location**: | + | - **storage_location**: |
==== Running Modes ==== | ==== Running Modes ==== | ||
Line 36: | Line 36: | ||
* Removes the ElectronRT DICOM Receiver from the Windows Services | * Removes the ElectronRT DICOM Receiver from the Windows Services | ||
* **service_restart.bat** | * **service_restart.bat** | ||
- | * Restarts the Service if changes are made to the configuration file. | + | * Restarts the Service if changes are made to the configuration file |
- | ---- | + | === 2. Running as a Stand Alone Application === |
- | + | ||
- | === 1. Running as a Stand Alone Application === | + | |
The ElectronRT DICOM Receiver can be run as a stand alone application. This option does not require administrative privileges. | The ElectronRT DICOM Receiver can be run as a stand alone application. This option does not require administrative privileges. | ||
Line 49: | Line 47: | ||
Notes: | Notes: | ||
- | * Any time the Computer is restarted (e.g.: windows updates) the stand along application will need to be manually run. | + | * Any time the Computer is restarted (e.g.: windows updates) the stand alone application will need to be manually run again. |
- | * Any time the receiver_configuration.json file is changed, the application will need to be manually restarted to load the new configuration | + | * Any time the receiver_configuration.json file is changed, the application will need to be manually restarted to load the new configuration. |
- | ===== ElectronRT DICOM Monitoring ===== | ||
+ | ---- | ||
+ | |||
+ | |||
+ | ===== ElectronRT DICOM Monitoring and Patient Import ===== | ||
+ | |||
+ | The following items detail the steps required to configure and use the patients received from the ElectronRT DICOM Receiver within the ElectronRT application: | ||
+ | - Users must set the DICOM Import Monitoring Directory within the [[electronrt: | ||
+ | - Once the monitoring directory has been set the [[[[electronrt: | ||
+ | |||
+ | <WRAP center round important 60%> | ||
+ | **Note:**\\ | ||
+ | Patient files stored temporarily within the DICOM Import Monitoring Directory are unencrypted DICOM files that may contain PHI. Please ensure this folder is located on your facility' | ||
+ | </ | ||
+ | |||
+ | |||
+ | < |
electronrt/userguide/dicom_receiver.1615995396.txt.gz · Last modified: 2021/07/29 18:22 (external edit)