===== DICOM Receiver ===== | ===== DICOM Receiver ===== | ||
- | The following guide details how to download, install, and configure the ElectronRT DICOM Receiver to automatically accept and import files into the ElectronRT application | + | The following guide details how to download, install, and configure the ElectronRT DICOM Receiver to automatically accept and import files into the ElectronRT application. |
==== Download and Installation ==== | ==== Download and Installation ==== | ||
- | - Download the ElectronRT DICOM Receiver via FIXME | + | - Download the ElectronRT DICOM Receiver via contacting .decimal for a secure download (note: future versions of eRT will include a DICOM receiver packaged with the application). |
- Extract the ElectronRT_dicom_receiver.zip file to an appropriate directory of your choosing (e.g.: C: | - Extract the ElectronRT_dicom_receiver.zip file to an appropriate directory of your choosing (e.g.: C: | ||
- Edit the receiver_config.json file to set the following fields: | - Edit the receiver_config.json file to set the following fields: | ||
- | - **local_ae_title**: | + | - **local_ae_title**: |
- | - **local_port**: | + | - **local_port**: |
- | - **timeout**: | + | - **timeout**: |
- | - **storage_location**: | + | - **storage_location**: |
==== Running Modes ==== | ==== Running Modes ==== | ||
Line 36: | Line 36: | ||
* Removes the ElectronRT DICOM Receiver from the Windows Services | * Removes the ElectronRT DICOM Receiver from the Windows Services | ||
* **service_restart.bat** | * **service_restart.bat** | ||
- | * Restarts the Service if changes are made to the configuration file. | + | * Restarts the Service if changes are made to the configuration file |
Line 47: | Line 47: | ||
Notes: | Notes: | ||
- | * Any time the Computer is restarted (e.g.: windows updates) the stand along application will need to be manually run. | + | * Any time the Computer is restarted (e.g.: windows updates) the stand alone application will need to be manually run again. |
- | * Any time the receiver_configuration.json file is changed, the application will need to be manually restarted to load the new configuration | + | * Any time the receiver_configuration.json file is changed, the application will need to be manually restarted to load the new configuration. |
Line 58: | Line 58: | ||
The following items detail the steps required to configure and use the patients received from the ElectronRT DICOM Receiver within the ElectronRT application: | The following items detail the steps required to configure and use the patients received from the ElectronRT DICOM Receiver within the ElectronRT application: | ||
- | - Users must a DICOM Monitoring Directory within the [[electronrt: | + | - Users must set the DICOM Import |
- | - The decimal ElectronRT User Guide section | + | - Once the monitoring directory has been set the [[[[electronrt: |
+ | |||
+ | <WRAP center round important 60%> | ||