+ | The ElectronRT application has two methods for importing new DICOM patients: 1) Manually browsing for local files and 2) setting up a DICOM receiver to accept and import DICOM patients. Refer to the sections below for details on each option. | ||
+ | ==== Local File Import ==== | ||
If you have a set of Ct Images and structures you can import them directly into a new patient through the " | If you have a set of Ct Images and structures you can import them directly into a new patient through the " | ||
< | < | ||
- | |||
- | Selecting the " | ||
< | < | ||
- | Here you may either browse your computer or copy the path to the folder that contains the CT images and structures you wish to import. | + | The Import DICOM Files option allows |
+ | * **Add Folder:** Browse for an entire folder of DICOM files to import into a patient | ||
+ | * Use recursive folder search: This option can be selected prior to adding a folder to reclusively search and add all DICOM files within the selected folder and all sub-folders. | ||
+ | * **Add Files:** Browse for individual DICOM file(s) to import into a patient. Note: this option does not make use of the recursive folder search option. | ||
- | Then the import will process: | + | A list of selected DICOM files for import will be displayed and you can choose to add more files for the selected patient or remove any files as desired. |
+ | |||
+ | Refer to the [[electronrt: | ||
+ | |||
+ | ==== DICOM Receiver Imports ==== | ||
+ | |||
+ | Users can install and configure the [[electronrt: | ||
+ | |||
+ | Users can then specify a DICOM Import Monitoring Directory within the [[electronrt: | ||
+ | |||
+ | < | ||
+ | |||
+ | Each patient received from the ElectronRT DICOM Receiver can be imported or removed from within the eRT Import Patient block. | ||
+ | |||
+ | Refer to the [[electronrt: | ||
+ | |||
+ | ==== Processing Imports ==== | ||
+ | |||
+ | |||
+ | Clicking the Import button will start processing the selected files. | ||
< | < | ||
Line 28: | Line 51: | ||
< | < | ||
- | If there are errors please refer to the [[electronrt: | + | If there are errors, please refer to the [[electronrt: |
+ | |||
+ | ==== Importing DICOM Plans ==== | ||
+ | |||
+ | Users have the option to import DICOM Plan files in addition to CT images and structure sets. For now, only electron plans can be imported into the decimal ElectronRT app. When importing a new patient, the DICOM plan file must have the proper UIDs that reference the structure set in order for the plan to be successfully imported. An imported plan will appear under the course of the new patient and will be marked as imported. | ||
+ | |||
+ | Refer to the [[electronrt: | ||
===== Common Errors ===== | ===== Common Errors ===== | ||
Line 34: | Line 64: | ||
If the imported DICOM Structure Set does not have a structure flagged as //RT ROI Interpreted Type (3006,00A4) EXTERNAL// you will be directed to specify the external patient structure before the import resumes. The patient external structure must be set to the defining boundary of the patient' | If the imported DICOM Structure Set does not have a structure flagged as //RT ROI Interpreted Type (3006,00A4) EXTERNAL// you will be directed to specify the external patient structure before the import resumes. The patient external structure must be set to the defining boundary of the patient' | ||
- | Note: You will be warned if the selected external structure is not the structure with the largest volume. This is to prevent incorrect structure selection | + | Note: You will be warned if the selected external structure is not the structure with the largest volume. This is to prevent incorrect structure selection. |
< | < | ||
- | The drop down menu will have a list of the structures in the imported set. You will be able to select one as the external for this course then confirm your choice by pressing "Set External" | + | The drop down menu will have a list of the structures in the imported set. You will be able to select one as the external for this course then confirm your choice by pressing "Set External" |
< | < | ||
Line 45: | Line 75: | ||
Structures can be skipped during Structure Set import if the structures meet the following criteria: | Structures can be skipped during Structure Set import if the structures meet the following criteria: | ||
- | * Non closed planar (e.g.: points or structures where slices are not correctly | + | * Non closed planar (e.g.: points or structures where slices are not fully closed) |
Structures that are skipped will be denoted at the end of the DICOM import as shown in <imgref import_skipped_structures> | Structures that are skipped will be denoted at the end of the DICOM import as shown in <imgref import_skipped_structures> | ||
Line 53: | Line 83: | ||
==== Importing an Existing Patient ==== | ==== Importing an Existing Patient ==== | ||
- | If the files you have selected to import coincide with the MRN of a patient that already exists in the app you will receive this error. | + | If the files you have selected to import coincide with the MRN of a patient that already exists in the database |
< | < | ||
Line 63: | Line 93: | ||
=== Import to a New Course === | === Import to a New Course === | ||
- | Importing to a new course will simply complete the import | + | Importing to a new course will simply complete the import |
< | < | ||
Line 69: | Line 99: | ||
=== Re-import Structures=== | === Re-import Structures=== | ||
- | Re-Importing structures can be used if your goal is to update or add structures to your existing patient. | + | Re-Importing structures can be used if your goal is to update or add structures to an existing patient |
< | < | ||
Line 88: | Line 118: | ||
=== Do Nothing=== | === Do Nothing=== | ||
- | This is the simplest action, selecting | + | This is the simplest action, selecting |
< | < | ||