electronrt:userguide:tutorials:dicom_import [2021/03/17 17:52] – [DICOM Receiver Imports] dpatenaudeelectronrt:userguide:tutorials:dicom_import [2022/03/08 15:49] (current) – [Importing DICOM Plans] anegron
Line 10: Line 10:
 ===== Importing a New Patient ===== ===== Importing a New Patient =====
  
-The ElectronRT application has two methods for importing new DICOM patients: 1) Manually browsing for local files and 2) setting up a DICOM receiver to accept and import DICOM patients. Refer to each options section below for details.+The ElectronRT application has two methods for importing new DICOM patients: 1) Manually browsing for local files and 2) setting up a DICOM receiver to accept and import DICOM patients. Refer to the sections below for details on each option.
 ==== Local File Import ==== ==== Local File Import ====
  
Line 16: Line 16:
  
 <imgcaption import_1|Import in the Main App Page>{{ :electronrt:userguide:tutorials:decimal_electronrt_import_new.png?direct&400 |}}</imgcaption> <imgcaption import_1|Import in the Main App Page>{{ :electronrt:userguide:tutorials:decimal_electronrt_import_new.png?direct&400 |}}</imgcaption>
- 
-Selecting the "Import New Patient" option will open the Importing UI. 
  
 <imgcaption import_2|Import Directory Input>{{ :electronrt:userguide:tutorials:decimal_electronrt_import_browse.png?direct&400 |}}</imgcaption> <imgcaption import_2|Import Directory Input>{{ :electronrt:userguide:tutorials:decimal_electronrt_import_browse.png?direct&400 |}}</imgcaption>
  
-Here you may either browse your computer or copy the path to the folder that contains the CT images and structures you wish to import. FIXME0.0.Add in new DICOM browser options. Refer to the [[electronrt:userguide:tutorials:dicom_import#processing_imports|Processing Imports]] section once files have been selected to import.+The Import DICOM Files option allows you to either browse your computer or copy the path to the folder that contains the CT images and structures you wish to import. The following options are available for browsing for local files: 
 +  * **Add Folder:** Browse for an entire folder of DICOM files to import into a patient 
 +    * Use recursive folder search: This option can be selected prior to adding a folder to reclusively search and add all DICOM files within the selected folder and all sub-folders. 
 +  * **Add Files:** Browse for individual DICOM file(s) to import into a patient. Note: this option does not make use of the recursive folder search option. 
 + 
 +A list of selected DICOM files for import will be displayed and you can choose to add more files for the selected patient or remove any files as desired. 
 + 
 +Refer to the [[electronrt:userguide:tutorials:dicom_import#processing_imports|Processing Imports]] section once files have been selected to import.
  
 ==== DICOM Receiver Imports ==== ==== DICOM Receiver Imports ====
Line 27: Line 32:
 Users can install and configure the [[electronrt:userguide:dicom_receiver|ElectronRT DICOM Receiver]] to receive and save patients for seamless importing into the ElectronRT application. Users can install and configure the [[electronrt:userguide:dicom_receiver|ElectronRT DICOM Receiver]] to receive and save patients for seamless importing into the ElectronRT application.
  
-Users can then specify a DICOM Import Monitoring Directory within the [[electronrt:userguide:tutorials:all_tutorials#dicom_settings| Site Configuration's DICOM Settings]] block that corresponds to the ''storage_location'' field set for the ElectronRT DICOM Receiver. Once the receiver and monitoring directory have been setup and configured, and DICOM patients sent to the ElectronRT DICOM Receiver will automatically show up within the Import Patients display as shown in <imgref dicom_receiver_patients>.+Users can then specify a DICOM Import Monitoring Directory within the [[electronrt:userguide:tutorials:all_tutorials#dicom_settings| Site Configuration's DICOM Settings]] block that corresponds to the ''storage_location'' field set for the ElectronRT DICOM Receiver. Once the receiver and monitoring directory have been setup and configured, any DICOM patients sent to the ElectronRT DICOM Receiver will automatically show up within the Import Patients display as shown in <imgref dicom_receiver_patients>.
  
 <imgcaption dicom_receiver_patients|DICOM Receiver Patients>{{ :electronrt:userguide:tutorials:dicom_import_receiver_patients.png?direct&400 |}}</imgcaption> <imgcaption dicom_receiver_patients|DICOM Receiver Patients>{{ :electronrt:userguide:tutorials:dicom_import_receiver_patients.png?direct&400 |}}</imgcaption>
Line 33: Line 38:
 Each patient received from the ElectronRT DICOM Receiver can be imported or removed from within the eRT Import Patient block. Each patient received from the ElectronRT DICOM Receiver can be imported or removed from within the eRT Import Patient block.
  
-Refer to the [[electronrt:userguide:tutorials:dicom_import#processing_imports|Processing Imports]] section once a patient has been selected to import.+Refer to the [[electronrt:userguide:tutorials:dicom_import#processing_imports|Processing Imports]] section once a patient has been selected for import.
  
 ==== Processing Imports ==== ==== Processing Imports ====
  
  
-Then the import will process:+Clicking the Import button will start processing the selected files.
  
 <imgcaption import_3|Import Loading screen>{{ :electronrt:userguide:tutorials:decimal_electronrt_import_in_process.png?direct&400 |}}</imgcaption> <imgcaption import_3|Import Loading screen>{{ :electronrt:userguide:tutorials:decimal_electronrt_import_in_process.png?direct&400 |}}</imgcaption>
Line 46: Line 51:
 <imgcaption import_4|Import Finalized>{{ :electronrt:userguide:tutorials:decimal_electronrt_import_complete.png?direct&400 |}}</imgcaption> <imgcaption import_4|Import Finalized>{{ :electronrt:userguide:tutorials:decimal_electronrt_import_complete.png?direct&400 |}}</imgcaption>
  
-If there are errors please refer to the [[electronrt:userguide:tutorials:dicom_import|Common Errors]] section below.+If there are errorsplease refer to the [[electronrt:userguide:tutorials:dicom_import|Common Errors]] section below for further details. 
 + 
 +==== Importing DICOM Plans ==== 
 + 
 +Users have the option to import DICOM Plan files in addition to CT images and structure sets. For now, only electron plans can be imported into the decimal ElectronRT app. When importing a new patient, the DICOM plan file must have the proper UIDs that reference the structure set in order for the plan to be successfully imported. An imported plan will appear under the course of the new patient and will be marked as imported. 
 + 
 +Refer to the [[electronrt:userguide:tutorials:all_tutorials#imported_plans|Imported Plans]] section for more information on imported plans. 
 ===== Common Errors ===== ===== Common Errors =====
  
Line 71: Line 83:
 ==== Importing an Existing Patient ==== ==== Importing an Existing Patient ====
  
-If the files you have selected to import coincide with the MRN of a patient that already exists in the app you will receive this error.+If the files you have selected to import coincide with the MRN of a patient that already exists in the database you will receive this error.
  
 <imgcaption errors_1|Existing Patient Error>{{ :electronrt:userguide:tutorials:decimal_electronrt_import_error_existing_patient_options.png?direct&400 |}}</imgcaption> <imgcaption errors_1|Existing Patient Error>{{ :electronrt:userguide:tutorials:decimal_electronrt_import_error_existing_patient_options.png?direct&400 |}}</imgcaption>
electronrt/userguide/tutorials/dicom_import.1616003528.txt.gz · Last modified: 2021/07/29 18:24 (external edit)