User Tools

Site Tools


electronrt:userguide:tutorials:plan_reports

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
electronrt:userguide:tutorials:plan_reports [2020/07/20 17:20] – [Header Logo] dpatenaudeelectronrt:userguide:tutorials:plan_reports [2021/07/29 18:28] (current) – external edit 127.0.0.1
Line 2: Line 2:
  
 The ElectronRT App allows PDF export of treatment plan reports. Treatment plan reports include all patient, plan, and beam data and can optionally include screen shots taken in the application. The ElectronRT App allows PDF export of treatment plan reports. Treatment plan reports include all patient, plan, and beam data and can optionally include screen shots taken in the application.
 +
 +**Note:** The Export block will be disabled if no machine or CT curve exists in the site configuration.
  
 <imgcaption report_overview|Plan Report UI>{{ :electronrt:userguide:tutorials:plan_report-overview.png?direct |}}</imgcaption> <imgcaption report_overview|Plan Report UI>{{ :electronrt:userguide:tutorials:plan_report-overview.png?direct |}}</imgcaption>
Line 7: Line 9:
 ===== Report Customization ===== ===== Report Customization =====
  
-The ElectronRT App provides options for customizing the exported plan report including: customizing the header logo and setting the different options for details that will appear on the report.+The ElectronRT App provides options for customizing the exported plan report including: customizing the header logo and setting the different options for details that will appear in the report.
  
 ==== Header Logo ==== ==== Header Logo ====
  
-By default the header logo is set to the logo of the application. The header logo can be optionally overridden by the user in the Organization Configuration block. For more information please see <link to site config wiki> FIXME.+By defaultthe header logo is set to the logo of the application. The header logo can be optionally overridden by the user in the Organization Configuration block. For more information please refer to the [[:electronrt:userguide:tutorials:all_tutorials#organization_settings| Organization Settings]].
  
-The header will be placed as shown in <imgref custom_header>. The header image is not scaled and is placed on the report at it'native size. +The header will be placed as shown in <imgref custom_header>. The header image is not scaled and is placed on the report at its native size. 
  
 <imgcaption custom_header|Custom Header>{{ :electronrt:userguide:tutorials:plan_report-customization.png?direct&400 |}}</imgcaption> <imgcaption custom_header|Custom Header>{{ :electronrt:userguide:tutorials:plan_report-customization.png?direct&400 |}}</imgcaption>
Line 33: Line 35:
 <imgcaption report_screenshots|Report Screenshots>{{ :electronrt:userguide:tutorials:plan_report-screenshots.png?direct |}}</imgcaption> <imgcaption report_screenshots|Report Screenshots>{{ :electronrt:userguide:tutorials:plan_report-screenshots.png?direct |}}</imgcaption>
  
-After specifying a name for the screenshot the application will allow the user to capture the current display and save the screen shot for the plan report.+After specifying a name for the screenshotthe application will allow the user to capture the current display and save the screen shot for the plan report.
  
 === Managing Screen Shots === === Managing Screen Shots ===
Line 43: Line 45:
 ==== Report Content ==== ==== Report Content ====
  
-By default plan reports will contain all plan information currently present in the treatment plan. Users can optionally chose to not export specific content to the treatment plan report including: dose reference points, density overrides, beams, or ordered hardware information.+By defaultplan reports will contain all plan information currently present in the treatment plan. Users can optionally choose to not export specific content to the treatment plan report including: dose reference points, density overrides, beams, or ordered hardware information.
  
 === Coordinate System (Equipment & IEC) === === Coordinate System (Equipment & IEC) ===
  
-By default the treatment plan report will export beam geometry information in the equipment coordinate system. Users can optionally chose to export beam coordinates using the IEC coordinate system as specified in the Machine Configuration. This option is provided as a checkbox in the Report Content Options section.+By defaultthe treatment plan report will export beam geometry information in the equipment coordinate system. Users can optionally choose to export beam coordinates using the IEC coordinate system as specified in the Machine Configuration. This option is provided as a checkbox in the Report Content Options section.
  
 The selected coordinate system option will be displayed on the treatment plan report as either "Equipment" or "IEC" as shown in the <imgref report_coordinate_system> below. The selected coordinate system option will be displayed on the treatment plan report as either "Equipment" or "IEC" as shown in the <imgref report_coordinate_system> below.
Line 53: Line 55:
 <imgcaption report_coordinate_system|Report Coordinate System>{{ :electronrt:userguide:tutorials:plan_report-coordinatesystem.png?direct&400 |}}</imgcaption> <imgcaption report_coordinate_system|Report Coordinate System>{{ :electronrt:userguide:tutorials:plan_report-coordinatesystem.png?direct&400 |}}</imgcaption>
  
-For more information on setting the IEC coordinate systems please see <link to site config wiki> FIXME.+For more information on setting the IEC coordinate systems please refer to the [[:electronrt:userguide:tutorials:all_tutorials#machine_settings| Machine Geometry Settings]].
electronrt/userguide/tutorials/plan_reports.1595265641.txt.gz · Last modified: 2021/07/29 18:24 (external edit)