Previous revision
pdotd:pdotd_versions [2022/10/20 14:24] – [p.d 5.4.5] dpatenaudepdotd:pdotd_versions [2024/08/13 20:08] (current) – external edit 127.0.0.1
Line 4: Line 4:
 ---- ----
 ====== Release Notes ====== ====== Release Notes ======
 +
 +===== p.d 5.4.8 =====
 +
 +August 13, 2024
 +
 +//What's New//
 +  * Improves conversion of 2D Sliced Contours to 3D Mesh, improving smoothness and accuracy of Structures and Boluses
 +
 +|  Before  |  After  |
 +|{{:pdotd:bolus57.png?400|}}|{{:pdotd:bolus58.png?400|}}|
 +
 +----
 +
 +===== p.d 5.4.7 =====
 +
 +May 31, 2024
 +
 +**NEW FEATURES**
 +
 +  * Adds a **Copy Beam** option by right clicking on a beam
 +  * Adds option to shift digitized electron blocks to allow fitting onto the user selected cone
 +  * Added a p.d app specific permission to allow patient initials in order file
 +
 +**GENERAL BUG FIXES AND UPDATES**
 +
 +  * Updated the Order Wizard and authentication processes to be less sensitive to short term connection interruptions
 +  * DICOM export is now allowed for invalid bolus designs (e.g. bolus extends off CT image bounds), but ordering remains blocked and error message text is improved
 +  * Updated Electron Aperture millability function to use more robust library, now matching Proton Apertures
 +  * Changes Reports to set material for blocks from the block data, not as a hardcode
 +  * Changes photon block material to Brass instead of Cerrobend in order files
 +  * Fixes the bolus structure name on Bolus PDF reports
 +  * Removes URL unfriendly characters from MRN (only for those using MRN in patient order files, this is RARE)
 +  * Updates the Order Wizard to check CompIDs for patient name on initial wizard load (prevents issue that allowed digitized EAs to have full names in CompID)
 +  * Adds options for news articles to contain images
 +  * Moves Order Tracking button to be more visible and adds commonly used action buttons to Welcome Page header
 +  * Fixes a bug allowing 10x6 to be selected when the block opening is larger than this size 
 +  * Updates maximum allowed cutout opening size for Elekta Electron blocks (size is now at applicator plane as per Elekta specifications)
 +  * Fixes a bug that could result in two EXTERNAL structures in an exported DICOM Structure Set file
 +  * Updates electron block display color from yellow to copper
 +  * Bolus Wizard now computes and displays the surface area and volume of each bolus
 +  * Forces user to select body for FlexiBol when “External” is not set during import
 +  * Disallow body and bolus as same structure when designing a bolus
 +  * Updated the “Structure as Bolus” option of the Bolus Wizard to compute and display the Volume, Surface Area, and Size of a bolus
 +
 +**PROTON UPDATES**
 +
 +  * Updates the Machine data and Machine Settings to support proton machines that have a single snout that holds multiple size AP/RC (e.g. via a tray)
 +  * Updates the Machine data and Machine Settings to allow a new proton RC/AP engraving option that uses the Beam Name and Device Accessory Code (also updated max characters to 52 for this option)
 +  * Updates the proton aperture tool size to match the latest manufacturing sizes and also allows smaller APs (i.e. Hitachi SRS) to use the recently added smaller diameter tool
 +  * Removes the warning regarding missing Range Compensators for proton PBS plans as RCs are rarely used for PBS
 +  * Updates the BEV window for proton plans to indicate sizes are shown as projected to the isocenter plane
 +  * Fixes a bug preventing use of proton aperture/range compensator “cores”
 +  * Fixes a bug that made the RingDiameter and maxRadius fields blank in proton order files (non-divergent apertures)
 +
 +----
  
 ===== p.d 5.4.6 ===== ===== p.d 5.4.6 =====
  
-October PENDING, 2022+October 27, 2022
  
 //What's New// //What's New//
-  * Added a [[direct:userguide#app_specific_permissions|Site Level application permission]] to decimal Direct to require p.d users as a site to enter Bill PO information for each order.+  * Added a [[direct:userguide#app_specific_permissions|Site Level application permission]] to decimal Direct to require p.d users at a site to enter Bill PO information for each order.
   * Updated the Electron Block Digitizer Wizard to show the original scanned image by default instead of the color corrected image.   * Updated the Electron Block Digitizer Wizard to show the original scanned image by default instead of the color corrected image.
   * Updated the Electron Block Digitizer Wizard to always hide the automatic orientation button to be more intuitive to users where auto orientation fails.   * Updated the Electron Block Digitizer Wizard to always hide the automatic orientation button to be more intuitive to users where auto orientation fails.
Line 20: Line 75:
     * Changed the default "Point Spacing" to "Fine" if field size less than 8cm     * Changed the default "Point Spacing" to "Fine" if field size less than 8cm
     * Changed the default "Depth Beyond Target" to 1cm     * Changed the default "Depth Beyond Target" to 1cm
-    * Changed the default "Distal PTV Dose" to 80% if field size less than 8x8 AND energy less than 7MeV+    * Changed the default "Distal PTV Dose" to 80% if field size less than 8x8 AND energy 9MeV and lower
     * Changed the default "Unmilled Margin" to 1.5cm     * Changed the default "Unmilled Margin" to 1.5cm
 +  * Updated the Bolus Wizard to include the normalization value in the wizard for added user convenience.
  
 //Bug Fixes// //Bug Fixes//