planning:userguide:tutorials:pbs_beams
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
planning:userguide:tutorials:pbs_beams [2019/08/20 12:48] – [Beam Creation] Added the button option for SOBP treatment rooms dwright | planning:userguide:tutorials:pbs_beams [2021/07/29 18:28] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 18: | Line 18: | ||
==== General Settings ==== | ==== General Settings ==== | ||
- | The //General// block is used to set general beam details including: | + | The //**General**// block is used to set general beam details including: |
- | * Beam label, description, | + | * Color, |
- | * The intended Geometric Target | + | |
- | * Also specified here is the //Spot Target// (PBS only), which will be used to define the extent of the pbs spot placements for the beam. The spot target can either match the geometric target, or the user can choose to use the target for the fraction group in which the beam is used (this is a useful option as it allows the same geometric beam to be used in multiple fraction groups by simply recomputing the spot positions based on the fraction group target). {{ : | + | |
+ | === PBS specific === | ||
+ | |||
+ | For PBS beams the following additional options will be available: | ||
+ | |||
+ | * // | ||
+ | * //**Spot Target**// is used to define the extent of the PBS spot placements for the beam. The spot target can either match the geometric target, or the user can choose to use the target for the fraction group in which the beam is used (useful for allowing the same geometric beam to be used in multiple fraction groups by simply recomputing the spot positions based on the fraction group target). {{ : | ||
+ | |||
+ | === SOBP specific === | ||
+ | |||
+ | For SOBP beams the following additional options will be available: | ||
+ | |||
+ | * // | ||
+ | |||
+ | {{ : | ||
+ | |||
+ | * If the target selected is an existing beam, the new beam becomes a //**Patch beam**//. Thus, the targeted beam becomes a parent thru-beam of the current patch beam (child). | ||
+ | * The patch dose field box is then enabled, allowing users to enter a dose value amount. The parent beam's target will reduced such that any portion receiving a dose from the parent beam that is greater than this amount will be ignored when designing the patch beam range compensator. In other words, the target of the patch beam becomes the target of the parent beam, minus the volume enclosed by the isodose surface (compute only for parent beam) at the defined patch dose value. This patch beam target can be viewed in the Display UI and toggled on and off in the right hand side beam controls. | ||
+ | * Patch beams can also be " | ||
+ | * Also note, that once a beam is designated as a patch and added to a fraction group, it cannot be changed back to a standard non-patch beam. In such cases, you must either remove the beams from the Fraction Group first, or a new SOBP beam must be created. | ||
==== Beam Approach ==== | ==== Beam Approach ==== | ||
planning/userguide/tutorials/pbs_beams.1566305312.txt.gz · Last modified: 2021/07/29 18:25 (external edit)