User Tools

Site Tools


electronrt:electronrt_versions

This is an old revision of the document!


decimal eRT Version History

This section is intended to provide access to previous versions of the decimal ElectronRT (eRT) documentation. Below you will find the userguide for each released version of the decimal eRT app. To find your application's current version use the top “View” menu and select “App Info”; the “Version” field will contain your current version of the App.

User Guide information is directly available on this website for the current latest release and PDF files are provided for offline user guide access for all application versions below.


Release Notes

decimal eRT 0.0.2

February 24, 2021 - Download decimal eRT 0.0.2 User Guide

What's New

  • Adds Skin Collimator creation to electron beams
  • Adds the option to shift an isocenter position when creating an electron beam
  • Sliced views now jump to the center of the structure when a target is selected
  • Adds Intensity Modulator dose scaling controls during bolus creation
  • Adds default block margin to the Treatment Machine settings
  • Adds applicator to bolus collision detection and errors
  • Bolus and Skin Collimator order files now contain Stereolithography (STL) file data

Bug Fixes

  • Fixed short patient names causing errors with comp IDs when ordering devices
  • Fixed the app being defaulted to full screen on initial application launch
  • Fixed checksum race condition and errors when saving a Course
  • Updated the treatment machine SAD vale to be a single textbox
  • Fixed the Elekta applicator field sizes to be the correct size at tray (5% larger)
  • Updated the BEV block & manual edit colors to better show the final block shape
  • Fixed the Uniform Thickess Bolus extents box being in the wrong distance unit
  • Fixed IM order files to have pins at the physical locations
  • Updated Bolus QA to includ eboth the original structures and the reimported structures (which are given a '_QA' suffix
  • Disabled the Beams and Export blocks when no treatment machine or CT curves are present in the organization configuration

Note: This release has not been cleared by the FDA for clinical use


decimal eRT 0.0.1

December 4, 2020 - Download decimal eRT 0.0.1 User Guide

What's New

  • This is the initial consortium application release
  • Initial UI and application, including treatment planning support for electron beams, blocks, and bolus devices.

Bug Fixes

  • N/A

Note: This release has not been cleared by the FDA for clinical use


electronrt/electronrt_versions.1614206043.txt.gz · Last modified: 2021/07/29 18:19 (external edit)